beautypg.com

Description of hart interface, Device diagnostics, Process variables – KROHNE OPTIFLEX 1300C EN User Manual

Page 167: Calibration management

background image

DESCRIPTION OF HART INTERFACE

9

167

OPTIFLEX 1300 C

www.krohne.com

03/2014 - 4000172306 - HB OPTIFLEX 1300 R07 en

Service Parameters 2

Intr Min Layer

Cust

/ Global Search Cyc...

Cust

/ Peak Detect Count

Cust

/

Pulse Loss Tolera...

Cust

/ Auto Calc Er

Cust

/ Linearity Activation

Cust

/

Empty Area

Cust

/ Full Area

Cust

/ Length Attenuation

Cust

/ Mech

Attenuation

Cust

Calibration Parameters

Offset Converter

Cust

/ Elect Calib

Ratio

Cust

/ Mech Calib Ratio

Cust

Maintenance Info

Service Number

Cust

/ Service

Date

Cust

/ Operator Name

Cust

Quick Setup Summary

Probe Type

Rd

/ Counterweight Type

Rd

/ Probe End Pulse

Rd

/ Product

Type

Rd

/ Air Flag

Rd

/ Number of Produ...

Rd

/ Product

Rd

/ Application

Type

Rd

/ Mix Flag

Rd

/ Application Mode

Rd

HART

TAG Number / Manufacturer

Rd

/ Model

Rd

/ Dev id

Rd

/ Polling Address

Device

Order Number

Rd

/ Version Number

Rd

/ Service Number

Rd

/ Ex

Approval

Rd

Field Software Version

Main CPU Version

Rd

/ Comp. CPU

Version

Rd

Device Diagnostics

Overview (General)

Primary variable out of limits

Rd

/ Non-primary variable out of limits

Rd

/ Primary variable analog output saturated

Rd

/ Primary variable

analog output fixed

Rd

/ Cold start

Rd

/ Configuration changed

Rd

/ Field

device malfunction

Rd

Critical (Errors)

Electronic Offset Out Of Range

Rd

/ Temperature Out of Range

Rd

/

Interface Measurement High

Rd

/ Reference Pulse Lost

Rd

/ Self Test

Failed

Rd

/ Level Measurement Lost

Rd

/ Interface Measurement Lost

Rd

/ Time Out Measurement Cycle

Rd

/ Tank Overfill

Rd

/ Reference

Pulse Lost Max Count

Rd

/ Front End Out of Order

Rd

/ Time Base

Faulty

Rd

/ 5 Volts Faulty

Rd

Informational (Warning)

Upper Current output1 has saturated

Rd

/ Upper Current output2 has

saturated

Rd

/ Lower Current output1 has saturated

Rd

/ Lower

Current output2 has saturated

Rd

/ Level measurement Low

Rd

/

Interface measurement Low

Rd

/ Layer measurement Low

Rd

/

Reference Pulse Low

Rd

/ Flange Pulse Lost

Rd

/ Level Pulse Lost

Rd

/

Interface Pulse Lost

Rd

/ Probe End Pulse Lost

Rd

/ Parasite Pulse

Near Flange

Rd

/ Parasite Pulse Found

Rd

/ Epsilon R Out Of Range

Rd

/

Deposit Factor Out Of Range

Rd

Process variables

Level

Rd

/ Distance

Rd

Primary Output

Primary Function

Rd

/ Distance I1

Rd

/ %Distance

Rd

Secondary Output

Secondary Function

Rd

/ Distance I2

Rd

/ %Distance

Rd

Calibration Management

Define Test...
Enter Test Data...
Calibration Status...
Calibration History...