3.8.7 Recommendations for pits and tanks made of non-conductive materials

If you have a device with a single rod or a single cable probe and a thread connection,
obey these instructions:

• Put a metal sheet between the device and the process connection.

i

It must have a diameter greater than 200 mm / 8¨.

• Make sure that the metal sheet is in contact with the thread stop on the device.

We recommend that you use DN≥200 / ≥8¨ for flange connections.

If you have a device with a double rod, double cable or coaxial probe, you can ignore these
instructions.

Figure 3-40: Installation in a non-metallic tank or pit with a thread connection

1 Non-metallic (plastic...) tank or pit
2 Metal sheet, Ø ≥200 mm / 8¨

CAUTION!