beautypg.com

Installation – KROHNE OPTIFLEX 1300C EN User Manual

Page 20

background image

3

INSTALLATION

20

OPTIFLEX 1300 C

www.krohne.com

03/2014 - 4000172306 - HB OPTIFLEX 1300 R07 en

Temperature ranges for gaskets

Process pressure limits

Gasket material

Process connection temperature

Standard version

High-Pressure version High-Temperature and

High-Temperature /

High-Pressure

versions

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

FKM/FPM

-40…+200

-40…+392

-40…+150

-40…+302

-40…+300

-40…+572

Kalrez

®

6375

-20…+200

-4…+392

-20…+150

-4…+302

-20…+300

-4…+572

EPDM

-50…+150

-58…+302

-50…+150

-58…+302

-50…+250

-58…+482

INFORMATION!
Ø4 mm / 0.16

Ø4 mm / 0.16

Ø4 mm / 0.16

Ø4 mm / 0.16

¨

single cable probe with FEP coating option only:

single cable probe with FEP coating option only:

single cable probe with FEP coating option only:

single cable probe with FEP coating option only: The process connection

temperature range is -20...+150

°

C / -4...+302

°

F

INFORMATION!
Single rod probes with protective sheath option only:

Single rod probes with protective sheath option only:

Single rod probes with protective sheath option only:

Single rod probes with protective sheath option only: The process connection temperature range
depends on the protective sheath material selected.
PP: -40...+90

°

C / -40

+194

°

F; PVDF: -40...+150

°

C / -40

+302

°

F; PVC: -15...+80

°

C / +5

+176

°

F

Device version

Maximum process pressure

[barg]

[psig]

Ø8 mm / 0.32¨ single cable

40

1

580

1

High-Pressure (HP) version

300

1

4350

1

All other probe types and device versions

100

1

1450

1

1 Refer also to "Pressure / temperature table for probe selection" in the "Technical data" section