beautypg.com

Installation – KROHNE OPTIFLEX 1300C EN User Manual

Page 25

background image

INSTALLATION

3

25

OPTIFLEX 1300 C

www.krohne.com

03/2014 - 4000172306 - HB OPTIFLEX 1300 R07 en

3.6.2 How to attach probes to the bottom of the tank

If the liquid is agitated or turbulent, you can attach the probe to the bottom of the tank. The
procedure to attach the probe depends on the type of probe used.

• Weld a tube with an internal diameter of 28...30 mm / 1.1...1.2¨ to the bottom of the tank.

i

Make sure the tube aligns with the process connection at the top of the tank.

• Lower the probe into the tank.
• Put the end of the probe into the tube.

The probe counterweight has a hole with an M8 internal thread. You can also select the
appropriate options and attach:

1 An anchoring rod
2 A turnbuckle

For more data, contact your supplier.

CAUTION!
Keep the probe straight.

Double rod Ø8 mm / 0.32¨

Figure 3-11: How to attach a double rod probe to keep it straight

Double cable Ø4 mm / 0.16¨

Figure 3-12: How to attach a double cable probe to keep it straight