10

APPENDIX

186

OPTIFLEX 1300 C

www.krohne.com

03/2014 - 4000172306 - HB OPTIFLEX 1300 R07 en

L

M

O

P

S

T

Layer

Layer

Layer

Layer

This is a display option. It gives the thickness of top product. The layer must
be more than 50 mm or 2¨ for accurate measurement of level and/or
interface. Refer to the diagrams at the end of this section.

Level

Level

Level

Level

This is a display option. It is the height from the bottom of the tank (user-
defined) to the surface of the top product (Tank height – distance). Refer to
the diagrams at the end of this section.

Mass

Mass

Mass

Mass

This is a display option. It shows the total mass of tank contents. Use a
mass table or a volume table to display measurement data with mass
units.

Measurement pulse

Measurement pulse

Measurement pulse

Measurement pulse

The device transmits a short, low-powered electrical pulse or wave
transmitted down a guide to the process. The process (or the probe end if
in TBF measurement mode) reflects the pulse back to the device.

Operators

Operators

Operators

Operators

Users who can choose how to display measurements. They cannot
configure the device in supervisor mode.

Probe

Probe

Probe

Probe

This is either a metallic cable or rod used to guide the measurement pulse
to the process.

Probe length

Probe length

Probe length

Probe length

Ordered length of probe, L, from the face of the flange to end of the guide. If
you ordered a cable probe, this includes the counterweight. Refer to the
diagrams at the end of this section.

Sensor length

Sensor length

Sensor length

Sensor length

Length, L', of from the face of the flange to end of the guide. If you ordered
a cable probe, this does not include the counterweight. Refer to the
diagram at the end of this section.

Supervisors

Supervisors

Supervisors

Supervisors

Users who can configure the device in supervisor mode. They cannot
configure the device in service mode.

TBF mode

TBF mode

TBF mode

TBF mode

Tank Bottom Following (TBF) mode. If the product has a low dielectric
constant, use this mode. TBF mode uses the end of the probe to indirectly
measure the tank contents.

TDR

TDR

TDR

TDR

Time domain reflectometry (TDR). The principle used by the device to
measure level and interface. For more data, refer to

Measuring principle

on page 127.

Threshold

Threshold

Threshold

Threshold

A number of limits set either manually or automatically by the signal
converter to identify the reflected measurement pulses from the level, the
interface and the probe end. Also refer to

Thresholds and parasitic signals

on page 92.

Top dead zone

Top dead zone

Top dead zone

Top dead zone

The distance from the flange to the top limit of the measuring range. Also
refer to

Measurement limits

on page 141.