Example for filename definition:

strcpy(taParam.m_szProgFileName, "TestBoard.mcp");

To Voltage Mask +12V

taParam.m_nVoltageMask |= BYTE (0x01 << 3);

To Mask Error 7

taParam.m_PEMask &= ~(LONGLONG(0x01 << 7));

!

ExOptions Structure

This structure contains options that are used in State Analyzer and Exerciser configuration.

The ExOptions parameters are listed below:

m_bLoopMaster

Defines if the TA660 will loop as a Master.
Zero : Off (default)
One : On

m_bMasterLoopCounter

Defines if the TA660 will loop as a Master for the specified number
of times or will loop indefinitely.
Zero : indefinitely (default)
One : On

m_nLoopCounter

Defines the number of loops the TA660 will perform as a Master.
Master loop counter between 1 – 255 (default = 1)

m_bMasterAbort

Defines if the TA660 should abort, as a Master, if no DEVSEL#
occurs.
Zero : Disabled
One : Enabled (default)

m_bAssertFrame

Defines if the TA660 should assert the FRAME# as a Master
Zero : Regardless of GNT#
One : After GNT# asserted (default)

m_bCompleteTransaction Defines if the TA660 should complete the transaction after GNT# is

deasserted.
Zero : Disabled (default)
One : Enabled

m_bTargetDisconnect

Defines how the TA660 completes the transaction on Target
disconnect.
Zero : Use same transaction (default)
One : Use next transaction

m_bTargetRetry

Defines how the TA660 should continue to complete the transaction
on Target Retry.
Zero : Infinite retries (default)
One : Advance to next

m_bLoopTarget

Defines if the TA660 will loop as a Target.
Zero : Off (default)
One : On

m_bTargetLoopCounter

Defines if the TA660 will loop as a Target for the specified number
of times or will loop indefinitely.
Zero : indefinitely (default)
One : On

m_nTrgLoopCounter

Defines the number of loops the TA660 will perform as a Target.
Target loop counter between 1 – 255 (default = 1)

m_BinAddr[65]

Defines the Base Address of the TA660 as a Target in hex.
Default is set to DO NOT CARE (XXXXXXXXXXXXXXXX);