Down/up-min-noise-mgn, Down/up-min-noise-mgn -49 – SMC Networks TigerAccess SMC7816M User Manual
Page 731
L
INE
P
ROFILE
C
OMMANDS
29-49
Example
The following sets an SNR of 12 dB for the downstream channels and 18
dB for the upstream channels.
Related Commands
down/up-min-noise-mgn
These commands set the minimum acceptable signal-to-noise margin on a
downstream/upstream channel. Use the no form to restore the default
settings.
Syntax
{down|up}-min-noise-mgn value
no {down|up}-min-noise-mgn
• down – Downstream bands.
• up – Upstream bands.
• value – Signal-to-noise margin. (Range: 0-62, in units of 0.5 dB)
Default Setting
10 dB
Command Mode
VDSL Line Profile
Command Usage
• This command sets the minimum noise margin the receiver can
tolerate. If the noise margin falls below this level, the receiver will ask
the sender to increase its transmit power. If it is not possible to
increase the transmit power, a loss-of-margin defect occurs, the link
will fail and the receiver will attempt to re-initialize.
Console(config-line-profile)#down-target-noise-mgn 12
Console(config-line-profile)#up-target-noise-mgn 18
Console(config-line-profile)#