Figure 4-15 system logs -30 – SMC Networks TigerAccess SMC7816M User Manual
Page 112
B
ASIC
M
ANAGEMENT
T
ASKS
4-30
• RAM Level – Limits log messages saved to the switch’s temporary RAM
memory for all levels up to the specified level. For example, if level 7 is
specified, all messages from level 0 to level 7 will be logged to RAM.
(Range: 0-7, Default: 7)
Note:The Flash Level must be equal to or less than the RAM Level.
Web – Click System, Logs, System Logs. Specify System Log Status, set the
level of event messages to be logged to RAM and flash memory, then click
Apply.
Figure 4-15 System Logs
4
Warning
Warning conditions (e.g., return false,
unexpected return)
3
Error
Error conditions (e.g., invalid input, default used)
2
Critical
Critical conditions (e.g., memory allocation, or
free memory error - resource exhausted)
1
Alert
Immediate action needed
0
Emergency
System unusable
* There are only Level 2, 5 and 6 error messages for the current firmware release.
Table 4-1 Logging Levels (Continued)
Level
Severity Name
Description