Min-protection, Min-protection -44, Vdsl c – SMC Networks TigerAccess SMC7816M User Manual
Page 726: 44 min-protection
VDSL C
OMMANDS
29-44
min-protection
This command configures the minimum level of impulse noise protection
for all bearer channels. Use the no form to restore the default setting.
Syntax
min-protection {down | up} value
no max-power {down | up}
• down – Downstream bands.
• up – Upstream bands.
• value – The number of consecutive DMT symbols for which errors
can be completely corrected. (Range: 0-255, in units of 0.5 DMT
symbols, or 125 microseconds)
Default Setting
0
Command Mode
VDSL Line Profile
Command Usage
• This minimum margin indicates the amount of increase in impulse
noise that the system can tolerate under operational conditions while
still ensuring required transmission quality.
• This command is used to set the time span of impulse noise
protection, as seen at the input to the de-interleaver, for which errors
can be completely corrected by the error correcting code, regardless of
the number of errors within the errored DMT symbols.
• Note that this parameter only applies to interleaved channels. Refer to
ITU-T G.993.2 for a full description of the methods used to calculate
the minimum level of impulse noise protection.
Example
Console(config-line-profile)#min-protection down 5
Console(config-line-profile)#