Table 10-9 cpe performance counters -37, Cpe i – SMC Networks TigerAccess SMC7816M User Manual
Page 289
D
ISPLAYING
CPE I
NFORMATION
10-37
CPE Performance Counters
Table 10-9 CPE Performance Counters
Parameter
Description
cpe perfermance counters
FeFEC_F
Far end Forward Error Correction on fast path
FeCRC_F
Far end CRC errors on fast path
FeFEC_S
Far end Forward Error Correction on slow path
FeCRC_S
Far end CRC errors on slow path
FeFLOS
Far end Loss of Signal
FeSEF
Far end Severely Errored Frame
FeFECUnCrr_F
Far end Forward Error Correction on fast path -
uncorrected errors
FeFECUnCrr_S
Far end Forward Error Correction on slow path -
uncorrected errors
INI Far End Counters (Ikanos Network Interface)
TX_FRAME_CNT
Transmitted frame count
RX_FRAME_CNT
Received frame count
TX_CRC_FRAME_CNT Transmitted frames with CRC errors
RX_CRC_FRAME_CNT Received frames with CRC errors
DROP_FRAME_CNT
Frames dropped due to data errors or buffer overflow.
Error Seconds
A one-second interval containing one or more CRC
anomalies, or one or more Loss of Signal (LOS) or
Loss of Framing (LOF) defects
VDSL Port CRS Errors
CRC errors on the VDSL port
SNR Margin and Attenuation
SNR Margin
Current signal-to-noise margin
Attenuation
Amount of attenuation in signal strength