Max-power, Max-power -43 – SMC Networks TigerAccess SMC7816M User Manual
Page 725
L
INE
P
ROFILE
C
OMMANDS
29-43
Example
The following disables all tone beneath 640 kHz on the upstream band
plan.
Related Commands
max-power
This command sets the maximum aggregate downstream or upstream
power. Use the no form to restore the default setting.
Syntax
max-power {down | up} value
no max-power {down | up}
• down – Downstream bands.
• up – Upstream bands.
• value – Maximum aggregate power. (Range: 0-255, in units of
0.25 dBm)
Default Setting
255 (63.75 dBm)
Command Mode
VDSL Line Profile
Example
The following sets the maximum downstream power to 14.5 dBm.
Related Commands
Console(config-line-profile)#tone tx 2
Console(config-line-profile)#
Console(config-line-profile)#max-power down 58
Console(config-line-profile)#