Logic 101:the logic for various apparatus, Operation example (logic 101) – IDEC FS1A Controller User Manual
Page 54

LOGIC
5-6
Logic 101: The logic for various apparatus
Overview (Logic 101)
This logic is for safety protective measures applicable to production machines and robots. Safety
outputs perform as dual channel outputs.
This logic enables the connection of 2 dual channel direct opening inputs and 4 dual channel
dependent inputs.
System runs
Safety input 1
Safety input 2
Safety input 4
Safety input 3
Safety input 5
Safety input 6
Safety output 1
or
Safety output 2
Emergency
stop switch
Safety switch
Logic 101
Safety
output 1
Safety
output 2
Operation example (Logic 101)
Safety input 1
Safety input 2
Safety input 4
Safety input 6
Safety input 3
Safety input 5
Safety output 1
or
Safety output 2
Open!
Press!
System stops