Logic circuit (logic 11d), 2k+1, Logic – IDEC FS1A Controller User Manual
Page 103: Monitor output for muting input

LOGIC
5-55
Chapter 5
Logic circuit (Logic 11d)
X0, X1
X2, X3
X4, X5
X6, X7
T12, X12, T13, X13
T10, X10, T11, X11
T14, X14
T15, X15
X16
X17
Safety input 1
Safety input 4
Safety input 3
Muting input 2
Safety input 2
Muting input 1
Start input 1
Start input 2
External device
monitor 2
External device
monitor 1
Muting
Muting
Y0
Y1
Y2
Y3
Safety output 1
&
=2k+1
Control
Contorl
Start
Hold
EDM
OSSD
Muting
function Ⅱ
Safety
input
Muting
( ∞ )
OS1
Dual Channel Safety
Dual Channel Safety
Hold
EDM
OSSD
with
Off delay
External Device
Monitor
EDM
External Device
Monitor
EDM
Single Channel
Monitor
Single Channel
Monitor
Dual Channel
Direct Opening
Dual Channel
Direct Opening
Hold
Trigger
Self-hold
function
Self-hold
function circuit 1
Muting
function Ⅱ
Safety
input
Muting
( ∞ )
OS1
Y12
Y13
X1
X0
Y4
X3
X2
Y5
X5
X4
Y6
X7
X6
Y7
X11
X10
Y10
X13
X12
Y11
●
Monitor output for safety input
●
Monitor output for safety output
●
Muting lamp output
X3
X2
Y17
X7
X6
Y20
Y0,Y1
Y2,Y3
Safety input 1
monitor
Muting input 1
monitor
Safety input 2
monitor
Muting input 2
monitor
Safety input 3
monitor
Safety input 4
monitor
Safety output 1
monitor
Safety output 2
monitor
(Note1)
●
Monitor output for muting input
&
&
&
&
&
&
&
&
&
Note1:
Safety output 2 monitor turns OFF
immediately independent of OFF-delay
time.
(Note2)
Note2:
The muting lamp output turns ON when
the safety function of the safety input is
temporarily suspended.
Even if the muting input is ON when the
safety output is OFF, the muting lamp
output doesn't turn ON.
In case of the SafetyOne is turned ON
when the muting input is ON or the
safety output turns OFF when the
muting input is ON, muting function is
not activated without turning off of muting
input.
Muting lamp output 2
Muting lamp output 1
(Note2)