LED Indicator Guide

Use the LEDs and the LCD display to determine the operating status.

Table 5-1, LED Indicator Guide

LED

Status

Meaning

PWR

(green)

OFF

1) Inverter is disabled; 2) Remote’s in Power Save mode –

press any button to activate LEDs; 3) No power to remote

(check remote cable or the power to the inverter); or, 4) No

AC power at the inverter’s AC output terminals.

ON

AC power is available from the inverter, utility, or generator at

the inverter’s AC output terminals.

FAULT

(red)

OFF

Normal operation.

ON

A fault condition has been detected. Check the LCD display to

fi nd and correct the cause.

CHG

(green)

OFF

1) Remote is in Power Save mode – press any button to

activate LEDs; or, 2) Charger off – no utility or AC generator

present.

ON

Bulk, Absorb, Float, or Equalize charge mode (see the LCD

display to determine charge status).

BLINKING, dis-

play says “Char-

ger Standby

The charger is in Charger Standby mode. This occurs when the

ON/OFF CHARGER button is pressed to disable the charger.

BLINKING,

display says

Full Charge” or

Silent

The charger is in Battery Saver mode. This mode monitors the

battery voltage level and only charges if the battery voltage

decreases to a low level. Silent mode will automatically start

charging when the ReBulk Volts setting is reached.

BLINKING,

display shows a

charging status

(i.e., Bulk, Ab-

sorb, Float)

The charger current is automatically decreased because:

1) Charger Back-off – the inverter’s internal temperature

is getting hot, the current is decreased to reduce/maintain

temperature; or, 2) Low AC Input Voltage – the input AC

voltage is low, the charger is disabled to help stabilize

incoming AC voltage to prevent AC disconnect.

BLINKING,

display does

not show any

charge status

The inverter is detecting AC voltage (from utility or an AC

generator) on the inverter’s AC input terminals.

INV

(green)

OFF

1) Inverter is disabled; or, 2) Remote is in Power Save mode -

press any button to activate the LEDs.

ON

Inverter is enabled – 1) Supplying AC power on the output;

or, 2) In Inverter Standby (if both INV and CHG LEDs are on);

the inverter will automatically supply AC power to the loads if

utility or generator power is lost.

BLINKING

Inverter is in Search mode (the AC load is below the SETUP:

02A Search Watts setting).