Magnum Energy Ignition Switch Lockout (MM-ISW) User Manual
Me-isw instruction sheet, M e -is w
ME-ISW Instruction Sheet
Part Number: 64-0024
1
Magnum Energy Inc.
1111 80th Street SW, Suite 250
Everett, WA, USA 98203
www.magnumenergy.com
Introduction
The ME-ISW (Ignition Switch Lockout) pigtail adapter is designed to automati-
cally DISABLE the inverter function when a 12 volt DC signal is supplied. This
is useful in applications where it may be desirable to prevent 120VAC inverter
loads from being powered while the vehicle ignition switch is turned on.
The ME-ISW pigtail adapter is simple to install and is used with inverters that
provide a Stack port, such as the ME, MS, MS-AE and RD Series inverters.
Installation
Refer to fi gure 2 to install the ME-ISW; ensure the following requirements:
1. The ME-ISW wire should be connected to a circuit downstream from the
vehicle ignition switch, so that 12VDC is available when the ignition switch
is on, and not available when the ignition switch is off. The circuit selected
should be protected by a fuse rated at 5 Amps DC maximum.
2. The
ME-ISW pigtail MUST be plugged into the Stack port on the inverter
as shown in fi gure 1.
Operation Steps
1. The inverter automatically shuts off and the inverter on/off button on the
inverter (and remote control, if connected) is disabled when the ignition
switch is turned on (provides 12VDC to the ME-ISW pigtail wire).
2. The inverter on/off button (on inverter and remote panel) can be used to
turn the inverter on/off when the ignition switch is turned off (removes 12VDC
from the ME-ISW pigtail wire).
Info: The charger will continue to function and is not affected by
the ME-ISW pigtail operation.
M E -IS W
m ust be
connected to
the S tack P ort
M E -IS W
IS
W
C om m unication P orts
on the Inverter /C harger
S tack
(red )
M agnum N et
(green )
R em ote
(blue )
B TS