beautypg.com

Magnum Energy DC Load Disconnect (ME-DCLD) User Manual

Me-dcld instruction sheet

background image

ME-DCLD Instruction Sheet

Part Number: 64-0021 Rev A

1

Magnum Energy Inc.

2211 West Casino Rd.

Everett, WA, USA 98204

www.magnumenergy.com

Introduction

The ME-DCLD (DC Load Disconnect) pigtail adapter is designed to provide a

means to DISABLE the inverter function when a 12 volt DC signal is removed.

This is useful in applications when a vehicle or boat is placed into storage

and the battery disconnect switch is turned off to disconnect all DC loads, the

inverter can also be automatically turned off if the ME-DCLD is installed.
The ME-DCLD pigtail adapter is simple to install and is used with inverters that

provide a Stack port, such as the ME, MS, MS-AE and RD Series inverters.

Installation

Refer to fi gure 2 to install the ME-DCLD; ensure the following requirements:
1.

Connect the ME-DCLD wire to a circuit so that 12VDC is available when the

battery disconnect switch is on, and not present when the battery disconnect

is off. The circuit selected should be protected by a fuse rated at 5 Amps DC

maximum.

Caution: If using 24 or 48 volts, place a 15k ohm (for 24VDC) or 25k

ohm (for 48VDC) resistor in-line with the red wire on the ME-DCLD

to ensure this increased voltage does not damage the inverter.

2. The

ME-DCLD pigtail MUST be plugged into the Stack port on the inverter

as shown in fi gure 1.

Operation Steps

1. The inverter’s ON/OFF button (and on remote control, if connected) can be

used to turn the inverter on/off when the Battery Disconnect Switch is on.
2. The inverter will turn off and the inverter’s ON/OFF button (and on remote

control, if connected) is disabled when the Battery Disconnect Switch is off.

Info: The charger will continue to function and is not affected by

the ME-DCLD pigtail operation.

M E -D C LD

m ust be

connected to

the S tack P ort

M E -D C L D

DCL

D

C om m unication P orts

on the Inverter /C harger

S tack

(red )
M agnum N et

(green )

R em ote

(blue )
B TS

(yellow )