Magnum Energy ME-ARC Remote User Manual

Magnum Energy Relay

background image

Magnum Energy, Inc.

PN: 64-0030-030 Rev C

Page 1 of 2

Inverter Compatibility Sheet for the ME-ARC with Revision 3.0/3.01

The ME-ARC has many advanced settings, and is designed to work with the advanced features in your Magnum
inverter and/or other Magnum devices (i.e., ME-AGS-N or ME-BMK). The ME-ARC communicates with your inverter
to allow these advanced features to be set up or enabled. However, when the ME-ARC is released with a new
software revision, some of the features and functionality in this remote may not be available in an inverter or
networked accessory that has an earlier software level. In this case, when the advanced setting is requested from
the ME-ARC to your inverter (or any other Magnum device networked with the inverter), this setting is not
recognized and will not function. Use the steps below to help you determine which ME-ARC (Revision 3.0/3.01)
menus/features are compatible with your inverter.

1. Go to:

http://magnumenergy.com/inverter-compatibility/

to determine your inverter’s compatibility level

(L1, L2, L3 or L4).

2. Use the table below to determine which ME-ARC ‘Features/Settings’ you want to use and what inverter

compatibility level is required (see ‘Inverter Model/Level Required’).

3. If your inverter compatibility level is the same or greater than the ‘Inverter Model/Level Required’, then

your inverter can support the device setting/feature you want.

4. If your inverter does not have the required compatibility level for a feature/setting you want, contact

Magnum Energy to determine if there is a software upgrade option for your inverter.

Main Menu

Menu Heading/Item

≥Level 1

≥Level 3 [1]

≥Level 3 [1][7]

≥Level 4

≥Level 1 [8]

01A DC Volts

≥Level 1

01B DC Amps

≥Level 1

01C Charge Time

≥Level 1

02A Output Volts

≥Level 4 [3]

02B Output Hz

≥Level 4

02C Load Amps

≥Level 4 [4]

02D Input Amps

≥Level 4 [4]

02E Inv/Chg Amps

≥Level 4 [4]

02F Input AC

(AC1) [F]

MSH Models only

02G Input AC2 [F]

MSH-RE Models

03A AGS Status

≥Level 1

03B DC Volts-AGS

≥Level 1

03C Gen Run Time

≥Level 1

03D AGS Temp

≥Level 1

03E Since GenRun

≥Level 1

04A BMK Status

≥Level 1 [7]

04B

SOC

≥Level 1 [7]

04C DC Volts-BMK

≥Level 1 [7]

04D DC Amps-BMK

≥Level 1 [7]

04E AH In/Out

≥Level 1 [7]

04F Reset AH Out

≥Level 1 [7]

04G Total AH Out

≥Level 1 [7]

04H Minimum VDC

≥Level 1 [7]

04I Maximum VDC

≥Level 1 [7]

01A Set Clock

≥Level 1

01B Contrast

≥Level 1

01C Backlight

≥Level 1

01D Power Save

≥Level 1

01E Temp Display

≥Level 1

02A Search Watts

≥Level 1

02B LBCO Setting

≥Level 2

02F Power Up Always

[F]

≥Level 1

≥Level 3 [7]

≥Level 3 [1]

≥Level 3 [1]

VDC Connect,

Time Connect,

AC-In Disabled

Read Only
Read Only
Read Only

OFF**

Multi-Stage

Auto Connect

Read Only
Read Only
Read Only
Read Only
Read Only
Read Only

Read Only
Read Only
Read Only
Read Only
Read Only
Read Only

12:00A**

Read Only

Read Only

Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only

10.0 VDC

5 Watts

Fahrenheit

15 Minute

50%**

100%**

100%

50%

14.1

11.0

6:00P

6:00A

Always OFF

Disconnect Volts= 9.0-15.9* (12V)
Connect SOC= 20-98%

Fahrenheit, Celsius
OFF, 5-50 watts (1 watt increments)
9.0-12.2* VDC
Connect Time= 12:00A-12:00P
Disconnect Time= 12:00A-12:00P
Connect Volts= 9.0-15.9* (12V)

Read only display
Read only display
Time= 12:00A-12:00P
0-100%
0-100%
OFF, 1-60 Minutes

Read only display
Read only display
Read only display
Read only display
Read only display
Read only display

Read only display
Read only display
Read only display
Read only display
Read only display
Read only display

ME-ARC (REVISION 3.0/3.01) COMPATIBILITY MATRIX

SETUP

ON, OFF

Disconnect

SOC=

21-100%

Read only display

Read only display

03 AGS Meters

04 BMK Meters

01 Remote Setup

FEATURES/SETTINGS

Auto Connect

Selections/Adjustments Range

Read only display

CTRL

01 DC Meters

01 ACIn Control

02 CHG Control [5]

02 AC Meters

[5]

User

setting

Read only display
Read only display
Read only display

03 Gen Control

Button

METER

Read only display
Read only display

SOC Connect [F]
Multi-Stage, Force Float, Restart Bulk
OFF, ON, AUTO
Read only display
Read only display

Default

setting

.

02 Invert Setup

02C AC In - Time

02D AC In - VDC

Inverter

Model/Level

Required

.

02E AC In - SOC [F]