Appendix A – ME-ARC Compatibility Matrix

© 2014 Magnum Energy, Inc.

Page 130

*

12-volt values shown; for 24v systems – x2, for 48v systems – x4.

** These settings return to the factory default setting when power to the remote is removed.
ME-ARC Compatibility Matrix Notes:
[1] Not available on MM/MM-E/MM-AE/MMS/MMS-E models.
[2] Activate AC Couple Mode using Battery Type: Custom with MS-PAE Series ≥Version 4.1.
[3] The AC meter displays are only accurate when used with MS-PE, MS-PAE or MSH Series

inverters. The meters do not display unless the inverter is ≥ Level 4.

[4] Level 2 and 3 inverters can be used, but:

Level 2 inverters are limited from 1.0-4.5 hours,
Level 3 inverters Level 3 inverters ≥Version 4.1 (and MMS Version 1.5) are limited from 1.5-6.5 hours.
Any setting outside these limited ranges are not recognized and reverts to the inverter’s

default absorption time (2.0 hours).

[5] Requires ≥Level 4 to display.
[6] SOC features require the ME-BMK (Battery Monitor Kit) to be installed.
[7] To manually turn the generator on with the remote, a ME-AGS-N Version 5.0 or higher is

required.

Button

Features/Settings

Model/

Level

Required

Default

Main

Menu

Menu

Heading/Item

Selections/

Adjustments Range

SETUP

06
PT

Setup

06A Battery Type

CC/

CV

Amps = 0-250 ADC

≥Level 1

20 ADC

Max CC/CV Time =

OFF, 0.1-25.5 Hrs

12.0 Hrs

Recharge = 9.0-16.0* V

12.0*

Hold CV Chg VDC

06B Absorb Done

Time = 0.1-25.5 Hrs

≥Level 1

2.0 Hrs

Amps = 0-250 ADC

20 ADC

SOC = 50-100% [6]

100%

06C Max Charge Rate 0-100%

≥Level 1

100%

06D Max Charge

Time

OFF, 0.1-25.5 Hrs

≥Level 1

12.0 Hrs

06E Bulk Start

Daily/SunUp = YES, NO

≥Level 1

YES

Volts = OFF, 9.0-16.0*

12.0*

SOC = OFF, 50-99% [6]

80%

06F PT Aux Relay

Engage Volts = 8.0-16.6*

≥Level 1

10.0*

Engage Delay = 0-127s, 1-127m

10 Sec

Disengage Volts = 8.0-16.6*

14.0*

Disengage Delay = 0-127 Sec,

1-127 Min

10 Sec

06G PT Alarm

ON Volts = 8.0-16.6*

≥Level 1

10.0*

ON Delay = 0-127s, 1-127m

10 Sec

OFF Volts = 8.0-16.6*

14.0*

OFF Delay = 0-127s, 1-127m

10 Sec

06H PowerSave PT

Display

OFF, 1 - 60 Min

≥Level 1

15 Min