Installation

2.5

Power-up Self Test

Info: All power to operate the remote control is provided by the inverter/charger

through the remote cable.

When the ME-ARC is first connected to an inverter, a power-up self test is initialized. During the

self test, the LCD automatically displays in sequence:

• “MAGNUM ENERGY Self Test”, then
• “(C)2010-2013, Connecting to...”, and then
• “ME-ARC V 4.0, INV/CHG V #.#”

The remote’s LEDs also change with the screens (see Figure 2-7).

FAULT

PWR

CHG

INV

MAGNUM ENERGY

Self Test

FAULT

PWR

CHG

INV

(C)2010-2013
Connecting to..

FAULT

PWR

CHG

INV

ME-ARC V 4.0

INV/CHG V #.#

No LEDs light

PWR lights green

FAULT lights red

CHG lights green

INV lights green

CHG lights green

INV lights green

After the self test is fi nished the remote displays “Set Clock”. Use the ARC’s SELECT knob to set

the correct time by selecting hour, minutes, and either AM or PM (see Figure 2-8 below, and the

Set Clock procedure on page 19). Once the ARC’s clock is set, the inverter Home screen displays.

Figure 2-7, Power-up Self Test Screens

Set Clock

Minute =

11:

18

A

Set Clock

Hour

= 11

:18A

Set Clock

AM-PM

=

11:18

A

[Inverter Status]

DC 12.6V 100A

Inverter Home screen