Menu maps, Figure 4-3, setup button menu map – Magnum Energy ME-ARC Remote User Manual

Page 49

background image

Page 42

© 2014 Magnum Energy, Inc.

Menu Maps

SETUP

[Status/Fault]

03 Charger Setup

continued….

SETUP button menu map continues on next page

03B VAC Dropout
80 VAC

03C Battery Type
Flooded

Set VAC Dropout

80 VAC

Set Battery Type
Flooded

Set VAC Dropout

AC1 = 80 VAC

Set VAC Dropout
AC2 = 70 VAC

Note: Shading denotes screens that

display with MSH-RE models only

Set CV Chg Done
Time = 2.0 Hrs

Set Max Charge
Amps = 200 ADC

Set Max CC/CV
Time = 12.0 Hrs

P

R

R

P

R

R

R

5A - 60A

Set AC1 Input
Amps = 30A

Set AC2 Input
Amps = 20A

P

R

R

Set AC Input
Amps = 30A

5A - 60A

R

R

R

03A AC Input
Amps = 30A

03A AC Input
Amps = 30A / 20A

P

P

P

03B VAC Dropout
80 VAC / 70 VAC

P

P

P

R 60-100 VAC,UPS Mode

60-100VAC

60-100VAC,UPS Mode

GEL, AGM1, AGM2,

Custom, CC/CV

R

5A - 60A

Set Float
Volts = 13.2

Set Absorb
Volts = 14.4

Set EQ Done
Time = 4.0 Hrs

Set EQ
Volts = 15.6

P

P

R

R

R

12.0 – 16.0 VDC

12.0 – 16.0 VDC

12.0 – 16.0 VDC

0.1 – 25.5 Hrs

R

P

P

P

Set CV Charge
Volts = 13.8

P

Set CV Chg Done
Time

P

R

OFF, 20-990 ADC

R

R

Hold CV Chg VDC
Amps

Set Recharge
Volts = 12.0

Set CV Chg Done
Amps = 20 ADC

P

P

12.0-16.0 VDC

0-250 ADC

0.1-25.5 Hrs

R

R

OFF, 0.1-25.5 Hrs

12.0-16.0 VDC

P

R

Figure 4-3, SETUP Button Menu Map