Setup

TECH: 03 Inv Model
Displays the model number of the connected Magnum inverter.

Info: When the 03 Inv Model menu item displays “Unknown”, the remote is unable to

determine the inverter model. This happens when the remote is connected to a later/

newer inverter model not recognized by an older remote. All remote menu selections

and features that are available in the inverter will function normally.
Info: When an inverter is stacked in parallel or series, a stacking indication follows the

model number. The indication will identify the following stacking conditions: “PM” –

Parallel Master; “PS” – Parallel Slave; “SM” – Series Master; “SS” – Series Slave.

TECH: 04 Fault History
These menus display a history of any inverter, AGS, and PT controller faults, and provide a way

to clear all recorded fault history.

Info: All recorded fault history displays will be retained (except for the day the fault

occurred), even if power is removed from the remote. If no fault history is recorded,

the display shows “No Fault History”.

• 04A Inv Faults – This menu displays a history of the last nine inverter/charger faults. Infor-

mation for each fault displays from the most recent fault (H1) to the earliest/past recorded

faults (H2 up to H9). Refer to Figure 3-16.

Fault mode

Fault history

number
Day(s) since

fault occurred

Time fault

occurred

Low Battery
H1 FETs: 75F

Low Battery
H1 11.4V – 0A

Inv/Chg

status when

fault occurred

Inv DC voltage

at time of fault

Inv DC amperage

at time of fault

BTS temp at

time of fault

Transformer

temp at time

of fault

FETs temp at

time of fault

Low Battery
H1 Charger Stand

Low Battery
H1 Tfmer: 77F

Low Battery
H1 BTS: 78F

Low Battery
H1 D- 0 12:23P

Figure 3-16, Inverter Fault History Screens

The top line of each inverter fault screen displays the inverter fault mode. The bottom line of the

fi rst inverter fault screen displays the fault history number, the number of days since this fault

occurred, and the time this fault occurred. Rotate the SELECT knob to display additional readings

for this particular fault history number (series of six screens for each fault). The following infor-

mation displays (in order) on the subsequent inverter fault history screens: status of the inverter

or charger as the fault occurred, DC voltage at the time of this fault, DC amperage at the time of

this fault, and temperatures of the BTS, transformer, and FETs at the time of this fault.
Continue to rotate the SELECT knob to display earlier faults (as applicable).
• 04B AGS Faults – Refer to Section 7.2.3.2 for detailed information on the AGS fault history

displays that are available using the ME-ARC remote’s TECH button.

• 04C PT Faults – Refer to Section 10.2.2.2 for detailed information on the PT fault history

displays that are available using the ME-ARC remote’s TECH button.

• 04D Clear Faults – This menu allows all recorded fault history information—includes fault his-

tory data for any inverter, AGS and PT controller that are network connected—to be cleared/

erased. Press and hold the SELECT knob until “HISTORY CLEARED” displays.

CAUTION:

Before using the Clear Faults feature,

be sure you do not want the fault

history data for any device (inverter, AGS, or PT controller). Once fault history data has

been cleared, it cannot be retrieved

.