Appendix A – ME-ARC Compatibility Matrix

© 2014 Magnum Energy, Inc.

Page 128

Button

Features/Settings

Model/

Level

Required

Default

Main

Menu

Menu

Heading/Item

Selections/

Adjustments Range

SETUP

03

Char-

ger

Setup

03C Battery Type

Gel, Flooded, AGM1, AGM2

≥Level 1

Flooded

Absorb (12.0-16.0)*

≥Level 3 [2]

14.4*

Float (12.0-16.0)*

13.2*

EQ (12.0-16.0)*

15.6*

EQ Done (0.1-25.5)

4.0 Hrs

CC/

CV

Max Charge =

OFF, 20-990ADC

≥Level 4

200ADC

CV Charge =

12.0-16.0* VDC

13.8*V

CV Chg Done = Time,

Amps, Hold CV Chg VDC

Time

Time = 0.1-25.5

2 Hrs

Max CC/CV Time =

OFF, 0.1-25.5 Hrs

12 Hrs

Recharge Volts =

12.0-16.0* VDC

12.0*V

Amps = 0-250 ADC

20 ADC

Max CC/CV Time =

OFF, 0.1-25.5 Hrs

12 Hrs

Recharge Volts =

12.0-16.0* VDC

12.0*V

Hold CV Chg VDC

03D Absorb Done

Time = 0.1-25.5 Hrs

≥Level 4 [4]

2.0 Hrs

Amps = 0-250 ADC

≥Level 4 [5]

20 ADC

SOC = 50-100%

≥Level 4 [5]

100%

03E Max Charge Rate

10-100%

≥Level 2

100%

0-100%

≥Level 3

03F Max Charge Time OFF, 0.1-25.5 Hrs

≥Level 4 [5]

12.0 Hrs

03G Final Charge

Stage

Multi, Float

≥Level 4 [5]

Multi

Silent Rebulk = 12-16V*

≥Level 4

12.0*V

03H EQ Reminder

Days

OFF, 1-255 Days

≥Level 1

OFF

04
AGS

Setup

04A Gen Run VDC

Start Volts = OFF, 9.0-15.9*

≥Level 1

11.5*V

Start Delay = 0-127s, 1-127m

120 Sec

Stop = 9.1-16.0*, Float

14.4*V

Stop Delay = 0-127s, 1-127m

120 Sec

04B Gen Run Time

OFF, ON – Start Time =

12:00A-11:45P

≥Level 1

OFF

Stop Time = 12:00A-11:45P

12:00A

04C Gen Run Amps

Start Amps = OFF, 5-60A

≥Level 4

OFF

Start Delay = 0-127s, 1-127m

120 Sec

Stop Amps = 4-59A

4A

Stop Delay = 0-127s, 1-127m

120 Sec

Custom