beautypg.com

Magnum Energy ME-ARC Remote User Manual

Page 136

background image

Appendix A – ME-ARC Compatibility Matrix

Page 129

Button

Features/Settings

Model/

Level

Required

Default

Main

Menu

Menu

Heading/Item

Selections/

Adjustments Range

SETUP

04
AGS

Setup

04D Gen Run SOC

OFF, Start Gen SOC = 20-99%

≥Level 1

[6]

OFF

Stop Gen SOC = 21-100%

90%

04E Gen Run Temp

Start = OFF, Ext Input, 65-95F

(18-35C)

≥Level 1

OFF

Run Time = 0.5-25.5 Hrs

2.0 Hrs

04F Max Gen Run

Time

OFF, 0.1-25.5 Hrs

≥Level 1

12.0 Hrs

04G Quiet Time

OFF, ON–Start = 12:00A - 11:45P

≥Level 1

OFF

Stop Quiet Time = 12:00A - 11:45P
Quiet Time Topoff = OFF, 30-120 Min

OFF

04H Gen Exercise

Days = OFF, 1-255 days

≥Level 1

OFF

Run Hour/Min/AM-PM = 12:00A -

11:45P
Run Time = 0.1-25.5 Hrs

1.0 Hrs

04I Gen Warm-up

Time

0-127 sec, 1-127 min

≥Level 1

60 Sec

04J Gen Cooldown

Time

0-127 sec, 1-127 min

≥Level 1

60 Sec

04K Gen 100% SOC

Start Days

OFF, 1-255 Days

≥Level 4

[5]

OFF

SOC Hour/Minute/AM-PM =

12:00A - 11:45P

05

BMK

Setup

05A Charge Eff

Auto, 50-99%

≥Level 1

[6]

Auto

05B AmpHour Size

200-2500 AH

≥Level 1

[6]

400 AH

06
PT

Setup

06A Battery Type

Gel, Flooded, AGM1, AGM2

≥Level 1

Flooded

CC/

CV

Max Charge = OFF, 20-990A

≥Level 1

200 ADC

CV Charge = 12.0-16.6* VDC

13.8*

CV Chg Done = Time, Amps,

Hold CV Chg VDC

Time

Time = 0.1-25.5

2.0 Hrs

Max CC/CV Time = OFF,

0.1-25.5 Hrs

12.0 Hrs

Recharge = 9.0-16.0* Volts

12.0*

Absorb (12.0-16.6)*

≥Level 1

14.4*

Float (12.0-16.6)*

13.2*

EQ (12.0-16.6)*

15.6*

EQ Done (0.1-25.5)

4.0 Hrs

Custom