Magnum Energy ME-ARC Remote User Manual
Magnum Energy Relay

Magnum Energy, Inc.
PN: 64-0030-040 Rev C
Page 1 of 4
Inverter Compatibility Sheet for the ME-ARC with Revision 4.0
The ME-ARC has many advanced settings, and is designed to work with the advanced features in your Magnum inverter
and/or other Magnum devices (i.e., ME-AGS-N or ME-BMK). The ME-ARC communicates with your inverter to allow
these advanced features to be set up or enabled. However, when the ME-ARC is released with a new software revision,
some of the features and functionality in this remote may not be available in an inverter or networked accessory that
has an earlier software level. In this case, when the advanced setting is requested from the ME-ARC to your inverter
(or any other Magnum device networked with the inverter), this setting is not recognized and will not function. Use the
steps below to help you determine which ME-ARC (Revision 4.0) menus/features are compatible with your inverter.
to determine your inverter’s compatibility level (L1,
L2, L3 or L4).
2. Use the table below to determine which ME-ARC ‘Features/Settings’ you want to use and what inverter
compatibility level is required (see ‘Inverter Model/Level Required’).
3. If your inverter compatibility level is the same or greater than the ‘Inverter Model/Level Required’, then your
inverter can support the device setting/feature you want.
4. If your inverter does not have the required compatibility level for a feature/setting you want, contact Magnum
Energy to determine if there is a software upgrade option for your inverter.
Main Menu
Menu Heading/Item
≥Level 1
≥Level 3 [1]
≥Level 3 [1][6]
≥Level 4
≥Level 1 [8]
04A PT Chg Ctrl
≥Level 1
04B PT Aux Relay Ctrl
≥Level 1
04C PT Alarm Control
≥Level 1
04D PT MPPT Sweep
≥Level 1
01A DC Volts
≥Level 1
01B DC Amps
≥Level 1
02A Output Volts
≥Level 4 [3]
02B Output Hz
≥Level 4 [3]
02C Load Amps
≥Level 4 [4]
02D Input Amps
≥Level 4 [4]
02E Inv/Chg Amps
≥Level 4 [4]
02F Input AC
(AC1)
MSH Models only
02G Input AC2
MSH-RE Models
03A Charge Time
≥Level 1
03B Since Absorb Done [F]
≥Level 1
03C Since EQ Start [F]
≥Level 1
04A AGS Status
≥Level 1
04B DC Volts-AGS
≥Level 1
04C Gen Run Time
≥Level 1
04D AGS Temp
≥Level 1
04E Since GenRun
≥Level 1
04F Since 100% [F]
≥Level 1 [7]
04G Hour Meter [F]
≥Level 1
04A BMK Status
≥Level 1 [7]
04B
SOC
≥Level 1 [7]
04C DC Volts-BMK
≥Level 1 [7]
04D DC Amps-BMK
≥Level 1 [7]
04E AH In/Out
≥Level 1 [7]
04F Reset AH Out
≥Level 1 [7]
04G Total AH Out
≥Level 1 [7]
04H Minimum VDC
≥Level 1 [7]
04I Maximum VDC
≥Level 1 [7]
04J Days Since 100% SOC [F]
≥Level 1 [7]
06A ACLD Status
≥Level 1
06B ACLD Power Diverted
≥Level 1
06C ACLD Temp
≥Level 1
06D Target Volts
≥Level 1
06E ACLD-X Version
≥Level 1
METER
06 ACLD Meters
[F]
Read Only
Read Only
Read only display
Read Only
Model displays/Read only display
Read Only
15 Min
Read Only
05 BMK Meters
Read only display
Read Only
Read only display
Read Only
Read Only
Resettable
Resettable
Read only display
Read Only
Read only display
Read Only
02 AC Meters [5]
03 Timers
VDC Connect,
Time Connect,
AC-In Disabled
Read Only
Read Only
Multi-Stage
Auto
Connect
Read Only
Resettable
Read Only
OFF**
Multi-Stage
DISENGAGE
OFF
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Resettable
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Display Resettable
Display Resettable
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Display Resettable
Display Resettable
Read only display
Read only display
Read only display
Read only display
Display Resettable
Read only display
Read only display
Read only display
ME-ARC (REVISION 4.0) COMPATIBILITY MATRIX
Read only display
Resettable
04 AGS Meters
FEATURES/SETTINGS
Auto Connect
Selections/Adjustments Range
Read only display
Read only display
Read only display
User
setting
Read only display
03 Gen Control
Button
Read only display
Read only display
Read Only
OFF, ON, AUTO
Multi-Stage, Charger Off, Start
(Float,
Bulk,
EQ)
DISENGAGE, VDC, FAULT, ENGAGE
5 Min, 15 Min, 1 Hour, Fixed
Read only display
Read only display
Read only display
CTRL
01 DC Meters
01 ACIn Control
02 CHG Control
OFF, VDC, FAULT, ON
04 PT Control
[F]
Default
setting
.
Inverter
Model/Level
Required
.
SOC Connect
Multi-Stage, Start Float, Restart Bulk