4 bmk remote status messages, 1 bmk remote operational and fault statuses, 2 bmk remote soc statuses – Magnum Energy ME-ARC Remote User Manual

Page 100

background image

© 2014 Magnum Energy, Inc.

Page 93

Using a BMK: Monitoring

8.2.4

BMK Remote Status Messages

A BMK status message may be an operational or fault message. Access the METER: 05A BMK Sta-

tus menu to view the BMK’s current operating status. The status is important when determining

if the BMK is working correctly, or for troubleshooting a BMK installation.

8.2.4.1 BMK Remote Operational and Fault Statuses

Refer to Table 8-1 for a brief description of the BMK operational and fault statuses that may dis-

play on your remote. Refer to Section 8.3.2 “Resolving BMK Faults using the ME-ARC” for help in

diagnosing and resolving BMK fault conditions.

Table 8-1, BMK Remote Operational and Fault Statuses

Status

Description

BMK Ready

Indicates the BMK is correctly communicating with the inverter/charger.

No Comm

The BMK is not communicating with the inverter/remote. This is a nor-

mal status if there is no BMK connected in the system.

BMK not present

If a BMK is installed, view the BMK sense module’s LED.

a) If the LED is green, disconnect the terminal block for 5 seconds, and

then reconnect it to ensure the terminal block is correctly seated into

the sense module.
b) If the LED is blinking red, there is no communication or there is an

unrecognizable communication on the network. Check the communi-

cation cable—ensure it is connected correctly. If the ME-BMK commu-

nication cable is missing, a standard 2-conductor telephone cable may

be temporarily substituted.

Factory Fault

The BMK has lost its factory-set internal calibration reference.

Power-up Fault

A fault occurred during the BMK’s power-up sequence.

Unknown Fault ## A fault code that is not recognized by the remote.

8.2.4.2 BMK Remote SOC Statuses

The following “SOC” statuses indicate the battery’s current state of charge. Access the METER:

05B Battery SOC menu to view the BMK’s current SOC status.
Note: If a fault condition (i.e., Factory, Power-up, or Unknown fault) is present and appears on

the 05A BMK Status display, it will also appear on the 05B Battery SOC display as well until it has

been resolved.

Table 8-2, BMK Remote SOC Statuses

Status

Description

Think’n

When the BMK sense module is first connected, the batteries need to

be fully charged (i.e., SOC = 100%) to establish a SOC reference point.
The BMK sense module is disconnected from power and the batteries

require a full charge before the remote display begins providing SOC

percentage information.

###%

The batteries are fully charged, the display has changed from “Think’n

to “100%” and is ready to provide accurate SOC percentage values.

Factory Fault

The BMK has lost its factory-set internal calibration reference.

Power-up Fault

A fault occurred during the BMK’s power-up sequence.

Unknown Fault ## A fault code that is not recognized by the remote.
No Comm

Refer to Table 8-1 above.