Appendix A – ME-ARC Compatibility Matrix

Page 127

Button

Features/Settings

Model/

Level

Required

Default

Main

Menu

Menu

Heading/Item

Selections/

Adjustments Range

METER

07 PT

Meters

07F Power to Bat

Now:

Read Only

displays

≥Level 1

Read

Only

Life:
Reset:

07G Ground Fault

Read Only display

07H PT Data

PT Data

07I Clear PT Data

History

Clear PT History

07J PT Version

Read Only display

SETUP

01

System

Setup

01A Set Clock

Time = 12:00A - 11:59P

≥Level 1

12:00A**

01B Screen Setup

Brightness = 0-100%

≥Level 1

50%**

Contrast = 0-100%

100%**

Pwr Save = OFF, 1-60 Min

15 Min

01C Temp Display

Fahrenheit, Celsius

≥Level 1

Fahren-

heit

01D Max Charge

Amps

OFF, 20-990 ADC

≥Level 1

200 ADC

01E Link PT CHG

settings

YES, NO

≥Level 1

YES

02

Invert

Setup

02A Search Watts

OFF, 5-50 Watts

≥Level 1

5 Watts

02B LBCO Setting

9.0-12.2*VDC

≥Level 2

10.0*V

02C AC In - Time

Connect Time = 12:00A - 11:45P

≥Level 3

[1]

6:00A

6:00P

Disconnect Time = 12:00A - 11:45P

02D AC In - VDC

Connect Volts = 9.0-15.9*

≥Level 3

[1]

11.0*V

Disconnect Volts = 9.1-16.0*

14.1*V

02E AC In - SOC

Connect SOC = 20%-99%

≥Level 3

[6]

80%

Disconnect SOC = 21%-100%

100%

02F Power Up Always OFF, ON

≥Level 1

OFF

03

Charger

Setup

03A AC Input Amps

AC1 Input Amps = 5-60

≥Level 1

[1]

30A

AC2 Input Amps = 5-60

MSH-RE

only

20A

03B VAC Dropout

AC1 = 60-100 VAC, UPS Mode

U.S.

Models

80 VAC

AC2 = 60-100 VAC

MSH-RE

Models

70 VAC

110-190 VAC, UPS Mode

Export

models

150 VAC