6 setting the parameters, See section 5.4.6 "setting the – SMA SI 3.0-11 User Manual
Page 31
SMA Solar Technology AG
5 Operation of the Sunny Island Inverter With the Sunny Remote Control
Operating Manual
SI30M-44M-60H-80H-BE-en-30
31
7. To exit the parameter page, switch to the higher level or switch to standard mode:
• Turn the button to the left until the return symbol appears in the first line.
• To switch to a higher menu level, turn the button to the left until
• To switch to standard mode, turn the button to the left until
• Press the button.
Tip:
5.4.6 Setting the Parameters
1. Switch to installer mode on the Sunny Remote Control (see Section 5.4.1, page 29).
2. Select the desired parameter. You can only set the parameters for
which < Set >
is shown in the second line in the display.
3. Press the button.
☑ The return symbol is flashing next to the value.
✖ Stop device to change the value? appears in the display.
The parameter can only be changed in standby mode.
• Stop the system (see Section 4.3, page 19).
✖ No permission to change the value appears in the display.
You are not allowed to change the parameter in installer mode.
• If you want to change the parameters for the battery, select the menu New Battery in the QCG
(see Section 10.8 "Replacing the Battery", page 78).
• For all other settings, select the menu New System in the QCG (see the Sunny Island inverter installation
manual).
4. To set the parameter, turn the button to the left or right.
5. Press the button.
☑ The Sunny Remote Control requests a confirmation of the set
parameter.
6. To confirm the value, turn the button to the right until Y is flashing and then press the button.
7. To discard the value, turn the button to the right until N is flashing and then press the button.