13  Directory of the Parameters in Installer Mode and Expert Mode

SMA Solar Technology AG

100

SI30M-44M-60H-80H-BE-en-30

Operating Manual

163# State

No.

Name

Description

Value

Explanation

163.01 BatMntStt

Status of the full charge or

equalization charge
If full charge or

equalization charge with

PV energy has not ended

after 24 hours,

163.01 BatMntStt

automatically switches to

On.

On

Full charge or equalization

charge active, energy is

drawn from the utility grid

✓ ✖

Wait

If sufficient PV energy is

available, full charge or

equalization charge active

Off

No full charge or

equalization charge active

163.02 SlfCsmpSOCArea

Current range of the state

of charge of the battery
In systems for increased

self-consumption and in

battery backup systems,

this parameter shows the

range in which the state of

charge of the battery

currently is.

PeakShaveSOC Range for prevention of

derating losses

✓ ✖

SlfCsmpSOC

Range for increased

self-consumption

PVResSOC

Range for maintaining the

state of charge of the

battery

BUResSOC

Range for the battery

backup system function

BatResSOC

Range for protection

against deep discharge

ProtResSOC

Range for protection in the

event of deep discharge

163.03 SlfCsmpSOCLim

Threshold of the current

day of the state of charge

of the battery for increased

self-consumption in %

(expert mode)
The battery can be used for

increased self-consumption

up to the displayed

threshold.

5% to 90%

✓ ✖