2 standard mode, 1 display of operating states – SMA SI 3.0-11 User Manual
Page 22

5 Operation of the Sunny Island Inverter With the Sunny Remote Control
SMA Solar Technology AG
22
SI30M-44M-60H-80H-BE-en-30
Operating Manual
5.2 Standard Mode
5.2.1 Display of Operating States
The Sunny Remote Control displays the following operating states until the Sunny Island is started.
Figure 4: Display of operating states (example Standby)
5.2.2 Information Page in Systems for Increased Self-Consumption and
Battery Backup Systems
When the Sunny Island is started, the Sunny Remote Control provides information on the status of the system for increased
self-consumption.
Figure 5: Energy flows and status messages of the Sunny Island
Position Designation
Explanation
A
Boot
The Sunny Island is initializing.
Error
The Sunny Island is in error status.
LBM 1
The Sunny Island is in battery protection mode 1.
LBM 2
The Sunny Island is in battery protection mode 2.
LBM 3
The Sunny Island is in battery protection mode 3.
Restart
The Sunny Island is performing a restart.
Shutdown
The Sunny Island is stopped.
Silent
The Sunny Island is in energy saving mode.
Standby
The Sunny Island is in standby mode or in time-controlled operation.
Startup
The Sunny Island is starting up.
Position Symbol
Designation
Explanation
A
Warning symbol
Symbol for warnings and errors that do not affect the Sunny Island
operation.
If this symbol is flashing, acknowledge the error or warning