13.6 T

o

uc

h Pr

obe D

a

ta Manag

e

ment

Feed for probing

Feed rate at which the TNC is to probe the workpiece.

Set-up clearance

In the setup clearance you define how far from the defined (or
calculated) touch point the probe is to be pre-positioned. The smaller
the value you enter, the more exactly must you define the touch point
position.

Maximum measuring range

If the stylus is not deflected within the defined path, the TNC outputs
an error message.