beautypg.com

Delete basic rotation: m143 – HEIDENHAIN TNC 320 (340 551-01) User Manual

Page 171

background image

HEIDENHAIN TNC 320

171

7.

4 Miscellaneous F

u

nctions f

o

r Cont

our

ing Beha

vior

Delete basic rotation: M143

Standard behavior

The basic rotation remains in effect until it is reset or is overwritten
with a new value.

Behavior with M143

The TNC erases a programmed basic rotation from the NC program.

Effect

M143 is effective only in the block in which it is programmed.

M143 becomes effective at the start of the block.

Automatically retract tool from the contour at an
NC stop: M148

Standard behavior

At an NC stop the TNC stops all traverse movements. The tool stops
moving at the point of interruption.

Behavior with M148

The TNC retracts the tool in the direction of the tool axis if, in the
LIFTOFF

column of the tool table, you set the parameter Y for the active

tool (see “Tool table: Standard tool data” on page 100).

Effect

M148 remains in effect until deactivated with M149.

M148 becomes effective at the start of block, M149 at the end of
block.

The function M143 is not permitted during a mid-program
startup.

The M148 function must be enabled by the machine tool
builder.

Remember that, especially on curved surfaces, the
surface can be damaged during return to the contour. Back
the tool off before returning to the contour!

In the CfgLiftOff machine parameter, define the value by
which the tool is to be retracted . In the CfgLiftOff