beautypg.com

4 setting the datum with a 3-d touch probe, Introduction, To set the datum in any axis (see figure at right) – HEIDENHAIN TNC 320 (340 551-01) User Manual

Page 422

background image

422

13 Touch Probe Cycles in the Manual and Electronic Handwheel Modes

13.4 Set

ting the D

a

tu

m with a 3-D T

o

uc

h Pr

obe

13.4 Setting the Datum with a 3-D

Touch Probe

Introduction

The following functions are available for setting the datum on an
aligned workpiece:

„

Datum setting in any axis with PROBING POS

„

Defining a corner as datum with PROBING P

„

Setting the datum at a circle center with PROBING CC

To set the datum in any axis (see figure at right)

8

Select the probe function by pressing the

PROBING POS soft key.

8

Move the touch probe to a starting position near the

touch point.

8

Select the probe axis and direction in which you wish

to set the datum, such as Z in direction Z–. Selection
is made via soft keys.

8

To probe the workpiece, press the machine START

button.

8

Datum:

Enter the nominal coordinate (e.g. 0) and

confirm your entry with the SET DATUM soft key.

8

To terminate the probe function, press the END key.

Note that during an active datum shift the TNC always
bases the probed value on the active preset (or on the
datum most recently set in the Manual operating mode),
although the datum shift is included in the position display.

Y

X

Z