beautypg.com

10 .8 a d ditional f u nctions – HEIDENHAIN TNC 320 (340 551-01) User Manual

Page 330

background image

330

10 Programming: Q Parameters

1

0

.8 A

d

ditional F

u

nctions

In the part program, program FN 16: F-PRINT, to activate the
output:

The TNC then outputs the file PROT1.TXT through the serial interface:

CALIBRAT. CHART IMPELLER CENTER GRAVITY

DATE: 27:11:2001

TIME: 8:56:34

NO. OF MEASURED VALUES : = 1

*******************************************

X1 = 149.360

Y1 = 25.509

Z1 = 37.000

*******************************************

MIN

Number of minutes from the real-time clock

SEC

Number of seconds from the real-time clock

DAY

Day from the real-time clock

MONTH

Month as a number from the real-time clock

STR_MONTH

Month as a string abbreviation from the real-
time clock

YEAR2

Two-digit year from the real-time clock

YEAR4

Four-digit year from the real-time clock

96 FN16:

F-PRINT

TNC:\MASKE\MASKE1.A/RS232:\PROT1.TXT

If you use FN 16 several times in the program, the TNC
saves all texts in the file that you have defined with the
first FN 16 function. The file is not output until the TNC
reads the END PGM block, or you press the NC stop
button, or you close the file with M_CLOSE.

In the FN16 block, program the format file and the log file
with their respective extensions.

If you enter only the file name for the path of the log file,
the TNC saves the log file in the directory in which the NC
program with the FN16 function is located.

You can output up to 32 Q parameters per line in the
format description file.

Code word

Function