beautypg.com

Displaying calibration values – HEIDENHAIN TNC 320 (340 551-01) User Manual

Page 419

background image

HEIDENHAIN TNC 320

419

13.2 Calibr

ating a T

o

uc

h T

rigg

e

r Pr

obe

Displaying calibration values

The TNC stores the effective length and radius, as well as the center
misalignment, for use when the touch probe is needed again. You can
display the values on the screen with the soft keys PARAMETER. The
TNC always uses the values from the touch probe management, even
it values are also entered in the tool table.

Make sure that you have activated the correct tool number
before using the touch probe, regardless of whether you
wish to run the touch probe cycle in automatic mode or
manual mode.