beautypg.com

Fn14: error: displaying error messages, 10 .8 a d ditional f u nctions – HEIDENHAIN TNC 320 (340 551-01) User Manual

Page 326

background image

326

10 Programming: Q Parameters

1

0

.8 A

d

ditional F

u

nctions

FN14: ERROR: Displaying error messages

With the function FN14: ERROR you can call messages under
program control. The messages were programmed by the machine
tool builder or by HEIDENHAIN. Whenever the TNC comes to a block
with FN 14 in the Program Run or Test Run mode, it interrupts the
program run and displays a message. The program must then be
restarted. The error numbers are listed in the table below.

Example NC block

The TNC is to display the text stored under error number 254.

Error number

Text

1000

Spindle?

1001

Tool axis is missing

1002

Tool radius too small

1003

Tool radius too large

1004

Range exceeded

1005

Start position incorrect

1006

ROTATION not permitted

1007

SCALING FACTOR not permitted

1008

MIRRORING not permitted

1009

Datum shift not permitted

1010

Feed rate is missing

1011

Entry value incorrect

1012

Wrong sign programmed

1013

Entered angle not permitted

1014

Touch point inaccessible

1015

Too many points

1016

Contradictory entry

1017

CYCL incomplete

1018

Plane wrongly defined

1019

Wrong axis programmed

1020

Wrong RPM

1021

Radius comp. undefined

1022

Rounding-off undefined

1023

Rounding radius too large

1024

Program start undefined

1025

Excessive subprogramming

1026

Angle reference missing

1027

No fixed cycle defined

1028

Slot width too small

1029

Pocket too small

1030

Q202 not defined

1031

Q205 not defined

1032

Enter Q218 greater than Q219

1033

CYCL 210 not permitted

1034

CYCL 211 not permitted

1035

Q220 too large

1036

Enter Q222 greater than Q223

1037

Q244 must be greater than 0

1038

Q245 must not equal Q246

1039

Angle range must be < 360°

1040

Enter Q223 greater than Q222

1041

Q214: 0 not permitted

Range of error numbers

Standard dialog text

0 ... 299

FN 14: Error code 0 .... 299

300 ... 999

Machine-dependent dialog

1000 ... 1099

Internal error messages (see table
at right)

The machine tool builder can change the FN14:ERROR
function. Refer to your machine manual.

180 FN14: ERROR = 254