beautypg.com

7 checking and changing q parameters, Procedure – HEIDENHAIN TNC 320 (340 551-01) User Manual

Page 324

background image

324

10 Programming: Q Parameters

1

0

.7 Chec

king and Changing Q

P

ar

amet

ers

10.7 Checking and Changing

Q Parameters

Procedure

You can check Q parameters when writing, testing and running
programs in all operating modes and, except in the test run, edit them.

8

If you are in a program run, interrupt it if required (for example, by
pressing the machine STOP button and the INTERNAL STOP soft
key). If you are in a test run, interrupt it.

8

To call Q parameter functions: Press the Q INFO soft

key in the Programming and Editing mode of
operation.

8

The TNC opens a pop-up window in which you can

enter the desired range for display of the Q
parameters or string parameters

8

In the Program Run Single Block, Program Run Full

Sequence and Test Run modes of operation, select
the screen layout Program + Status

8

Select the Program + Q PARAM soft key

8

Select the Q PARAMETER LIST soft key

8

The TNC opens a pop-up window in which you can

enter the desired range for display of the Q
parameters or string parameters

8

With the Q PARAMETER REQUEST soft key (available

only in Manual Operation, Program Run Full
Sequence and Program Run Single Block), you can
request individual Q parameters. To assign a new
value, overwrite the displayed value and confirm with
the OK.