Set the lifetime of the history

records in an NQA test

group

history-record keep-time keep-time

Optional

By default, the history records

in the NQA test group are kept

for 120 minutes.

Configure the maximum

number of history records

that can be saved in a test

group

history-record number number

Optional

By default, the maximum

number of records that can be

saved in a test group is 50

Configuring Optional Parameters Common to an NQA Test Group

Optional parameters common to an NQA test group are valid only for tests in this test group.

Unless otherwise specified, the following parameters are applicable to all test types and they can be

configured according to the actual conditions.

Follow these steps to configure optional parameters common to an NQA test group:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter NQA test group view

nqa entry admin-name

operation-tag

Enter test type view of a test group

type { dhcp | dlsw | dns | ftp |

http | icmp-echo | snmp | tcp |

udp-echo | udp-jitter | voice }

Configure the descriptive string for

a test group

description text

Optional

By default, no descriptive string is

available for a test group.

Configure the interval between two

consecutive tests for a test group

frequency interval

Optional

By default, the interval between

two consecutive tests for a test

group is 0 milliseconds, that is,

only one test is performed.

If the last test is not completed

when the interval specified by the

frequency command is reached, a

new test is not started.