To ensure that the device works normally, use the info-center logfile size-quota

command to set a logfile to be no smaller than 1 MB and no larger than 10 MB.

z

Use the info-center logfile switch-directory command to manually configure the directory

to which a log file can be saved. The configuration will be invalid after system reboot or the

primary/backup switchover.

Configuring Synchronous Information Output

Synchronous information output refers to the feature that if the user’s input is interrupted by

system output such as log, trap, or debugging information, then after the completion of system

output the system will display a command line prompt (a prompt in command editing mode, or a

[Y/N] string in interaction mode) and your input so far.

This command is used in the case that your input is interrupted by a large amount of system

output. With this feature enabled, you can continue your operations from where you were

stopped.

Follow these steps to enable synchronous information output:

To do…

Use the command…

Remarks

Enter system view

system-view

Enable synchronous information

output

info-center synchronous

Required

Disabled by default

z

If system information, such as log information, is output before you input any information

under the current command line prompt, the system will not display the command line

prompt after the system information output.

z

If system information is output when you are inputting some interactive information (non

Y/N confirmation information), then after the system information output, the system will not

display the command line prompt but your previous input in a new line.

Disabling a Port from Generating Link Up/Down Logging Information

By default, all the ports of the device generate link up/down logging information when the port

state changes. Therefore, you may need to use this function in some cases, for example:

z

You only concern the states of some of the ports. In this case, you can use this function to

disable the other ports from generating link up/down logging information.