beautypg.com

Private alarm group configuration example, Network requirements – H3C Technologies H3C S7500E Series Switches User Manual

Page 145

background image

8-11

[Sysname] snmp-agent target-host trap address udp-domain 1.1.1.2 params securityname

public

# Configure RMON to gather statistics on interface GigabitEthernet 2/0/1.

[Sysname] interface GigabitEthernet 2/0/1

[Sysname-GigabitEthernet2/0/1] rmon statistics 1 owner user1

[Sysname-GigabitEthernet2/0/1] quit

# Create an RMON alarm entry that when the delta sampling value of node

1.3.6.1.2.1.16.1.1.1.4.1 exceeds 100 or is lower than 50, event 1 is triggered to send traps.

[Sysname] rmon event 1 trap public owner user1

[Sysname] rmon alarm 1 1.3.6.1.2.1.16.1.1.1.4.1 5 delta rising-threshold 100 1

falling-threshold 50 1

# Display the RMON alarm entry configuration.

display rmon alarm 1

AlarmEntry 1 owned by null is Valid.

Samples type : delta

Variable formula : 1.3.6.1.2.1.16.1.1.1.4.1

Sampling interval : 5(sec)

Rising threshold : 100(linked with event 1)

Falling threshold : 50(linked with event 2)

When startup enables : risingOrFallingAlarm

Latest value : 0

# Display statistics for interface GigabitEthernet 2/0/1.

display rmon statistics GigabitEthernet 2/0/1

EtherStatsEntry 1 owned by user1-rmon is VALID.

Interface : GigabitEthernet2/0/1

etherStatsOctets : 57329 , etherStatsPkts : 455

etherStatsBroadcastPkts : 53 , etherStatsMulticastPkts : 353

etherStatsUndersizePkts : 0 , etherStatsOversizePkts : 0

etherStatsFragments : 0 , etherStatsJabbers : 0

etherStatsCRCAlignErrors : 0 , etherStatsCollisions : 0

etherStatsDropEvents (insufficient resources): 0

Packets received according to length:

64 : 7 , 65-127 : 413 , 128-255 : 35

256-511: 0 , 512-1023: 0 , 1024-1518: 0

After completing the configuration, you may query alarm events on the NMS. On the monitored

device, alarm event messages are displayed when events occur. The following is a sample

output:

[Sysname]

#Aug 27 16:31:34:12 2005 Sysname RMON/2/ALARMFALL:Trap 1.3.6.1.2.1.16.0.2 Alarm table

1 monitors 1.3.6.1.2.1.16.1.1.1.4.1 with sample type 2,has sampled alarm value 0 less

than(or =) 50.

Private Alarm Group Configuration Example

Network requirements

As shown in

Figure 8-4

, monitor the utilization rate of interface GigabitEthernet 2/0/1 when it is

receiving packets. When the utilization rate is higher than 80%, the system logs the event

locally and sends a trap to the NMS; when the utilization rate is lower than 5%, the system only

logs the event locally.