Private alarm group configuration example, Network requirements – H3C Technologies H3C S7500E Series Switches User Manual
Page 145
8-11
[Sysname] snmp-agent target-host trap address udp-domain 1.1.1.2 params securityname
public
# Configure RMON to gather statistics on interface GigabitEthernet 2/0/1.
[Sysname] interface GigabitEthernet 2/0/1
[Sysname-GigabitEthernet2/0/1] rmon statistics 1 owner user1
[Sysname-GigabitEthernet2/0/1] quit
# Create an RMON alarm entry that when the delta sampling value of node
1.3.6.1.2.1.16.1.1.1.4.1 exceeds 100 or is lower than 50, event 1 is triggered to send traps.
[Sysname] rmon event 1 trap public owner user1
[Sysname] rmon alarm 1 1.3.6.1.2.1.16.1.1.1.4.1 5 delta rising-threshold 100 1
falling-threshold 50 1
# Display the RMON alarm entry configuration.
AlarmEntry 1 owned by null is Valid.
Samples type : delta
Variable formula : 1.3.6.1.2.1.16.1.1.1.4.1
Sampling interval : 5(sec)
Rising threshold : 100(linked with event 1)
Falling threshold : 50(linked with event 2)
When startup enables : risingOrFallingAlarm
Latest value : 0
# Display statistics for interface GigabitEthernet 2/0/1.
EtherStatsEntry 1 owned by user1-rmon is VALID.
Interface : GigabitEthernet2/0/1
etherStatsOctets : 57329 , etherStatsPkts : 455
etherStatsBroadcastPkts : 53 , etherStatsMulticastPkts : 353
etherStatsUndersizePkts : 0 , etherStatsOversizePkts : 0
etherStatsFragments : 0 , etherStatsJabbers : 0
etherStatsCRCAlignErrors : 0 , etherStatsCollisions : 0
etherStatsDropEvents (insufficient resources): 0
Packets received according to length:
64 : 7 , 65-127 : 413 , 128-255 : 35
256-511: 0 , 512-1023: 0 , 1024-1518: 0
After completing the configuration, you may query alarm events on the NMS. On the monitored
device, alarm event messages are displayed when events occur. The following is a sample
output:
[Sysname]
#Aug 27 16:31:34:12 2005 Sysname RMON/2/ALARMFALL:Trap 1.3.6.1.2.1.16.0.2 Alarm table
1 monitors 1.3.6.1.2.1.16.1.1.1.4.1 with sample type 2,has sampled alarm value 0 less
than(or =) 50.
Private Alarm Group Configuration Example
Network requirements
As shown in
, monitor the utilization rate of interface GigabitEthernet 2/0/1 when it is
receiving packets. When the utilization rate is higher than 80%, the system logs the event
locally and sends a trap to the NMS; when the utilization rate is lower than 5%, the system only
logs the event locally.