2-17

Configuration prerequisites

A UDP echo test requires cooperation between the NQA server and the NQA client. Configure the

UDP listening function on the NQA server before the UDP echo test. For the configuration of the UDP

listening function, see

Configuring the NQA Server

.

Configuring a UDP echo test

Follow these steps to configure a UDP echo test

To do…

Use the command…

Remarks

Enter system view

system-view

Enter NQA test group view

nqa entry admin-name

operation-tag

Configure the test type as UDP

echo and enter test type view

type udp-echo

Required

Configure the destination address

for a test operation

destination ip ip-address

Required

By default, no destination IP

address is configured for a test

operation.

The destination address must be

the IP address of the listening

service configured on the NQA

server.

Configure the destination port

destination port port-number

Required

By default, no destination port

number is configured for a test

operation.

The destination port number must

be the port number of the listening

service configured on the NQA

server.

Configure the size of probe

packets sent

data-size size

Optional

100 bytes by default.

Configure the filler string of a

probe packet sent

data-fill string

Optional

By default, the filler string of a probe

packet is the hexadecimal number

00010203040506070809.

Specify a source port number for a

probe request in a test operation

source port port-number

Optional

By default, no source port number is

specified.