beautypg.com

Configuring a dlsw test, Configuration prerequisites, Configuring the collaboration function – H3C Technologies H3C S7500E Series Switches User Manual

Page 41

background image

2-21

Configuring a DLSw Test

A DLSw test is used to test the response time of the DLSw device.

Configuration prerequisites

Enable the DLSw function on the peer device before DLSw test.

Configuring a DLSw test

Follow these steps to configure a DLSw test:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter NQA test group view

nqa entry admin-name

operation-tag

Configure the test type as DLSw

and enter test type view

type dlsw

Required

Configure the destination address

for a test operation

destination ip ip-address

Required

By default, no destination IP

address is configured for a test

operation.

Configure the source IP address of

a probe request in a test operation

source ip ip-address

Optional

By default, no source IP address is

specified.

The source IP address must be

that of an interface on the device

and the interface must be up.

Otherwise, the test will fail.

Configure common optional

parameters

See

Configuring Optional

Parameters Common to an NQA

Test Group

Optional

Configuring the Collaboration Function

Collaboration is implemented by establishing collaboration entries to monitor the detection results of

the current test group. If the number of consecutive probe failures reaches the threshold, the

configured action is triggered.

Follow these steps to configure the collaboration function:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter NQA test group view

nqa entry admin-name

operation-tag