Displaying and maintaining sflow, Sflow configuration example, Network requirements – H3C Technologies H3C S7500E Series Switches User Manual
Page 180
11-3
To do…
Use the command…
Remarks
Specify the number of packets out
of which the interface will sample a
packet
sflow sampling-rate rate
Optional
200000 by default, that is, one out
of every 200000 packets is
sampled.
z
The sFlow agent and sFlow collector must not have the same IP address.
z
Currently, you can specify at most two sFlow collectors on the device.
z
The sFlow agent and sFlow collector must be configured with the same version of IP addresses.
Displaying and Maintaining sFlow
To do…
Use the command…
Remarks
Display sFlow configuration
information (on a distributed
device)
display sflow [ slot slot-number ]
Available in any view
Display sFlow configuration
information (on a distributed IRF
device)
display sflow [ chassis
chassis-number slot slot-number ]
Available in any view
sFlow Configuration Example
Network requirements
z
Host A and Server are connected to Switch through GigabitEthernet 2/0/1 and GigabitEthernet
2/0/2 respectively.
z
Host B works as an sFlow collector with IP address 3.3.3.2 and port number 6343, and is
connected to Switch through GigabitEthernet 2/0/3.
z
GigabitEthernet 2/0/3 belongs to VLAN 1, having an IP address of 3.3.3.1.
Run sFlow agent on Switch, and enable sFlow on GigabitEthernet 2/0/1 to monitor traffic on this
interface. Switch sends sFlow packets through GigabitEthernet 2/0/3 to Host B, which then analyzes
the sFlow packets and displays the results.