Fill the power supply with coolant -41, Fill the power supply with coolant – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 90
INSTALLATION
HPR260 Auto Gas
Instruction Manual
3-41
Fill the power supply with coolant
The system will take 11.4 – 15.1 liters (3 to 4 gallons) of coolant depending on the length of the torch leads and
whether the system has a local or remote ignition console.
Locate the CNC screen for manual pump
control. The pump needs to run to fill the
leads.
3
Add coolant to the power supply
until the tank is full and replace the
filler cap.
4
Add coolant to the power supply until
the tank is full.
1
Turn ON the power supply using the
remote ON/OFF switch or the CNC.
2
Caution: Using the wrong coolant can cause damage to the system. Refer to torch
coolant requirements in this section for more information.
Do not over fill the coolant tank.
5