beautypg.com

Fill the power supply with coolant -41, Fill the power supply with coolant – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 90

background image

INSTALLATION

HPR260 Auto Gas

Instruction Manual

3-41

Fill the power supply with coolant

The system will take 11.4 – 15.1 liters (3 to 4 gallons) of coolant depending on the length of the torch leads and
whether the system has a local or remote ignition console.

Locate the CNC screen for manual pump
control. The pump needs to run to fill the
leads.

3

Add coolant to the power supply
until the tank is full and replace the
filler cap.

4

Add coolant to the power supply until
the tank is full.

1

Turn ON the power supply using the
remote ON/OFF switch or the CNC.

2

Caution: Using the wrong coolant can cause damage to the system. Refer to torch

coolant requirements in this section for more information.

Do not over fill the coolant tank.

5