Power supply states -21, Power supply states – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 165
MAINTENANCE
HPR260 Auto Gas
Instruction Manual
5-21
Power supply states
Power supply states are displayed on the CNC screen. The diagnostic screen shown below is for reference.
State
code
Name
State
code
Name
00
Idle
11
Auto off
02
Purge
12
Test cutflow
03
Idle 2
14
Shutdown
04
Preflow
15
Reset
05
Pilot arc
16
Maintenance
06
Transfer
20
Test preflow
07
Ramp-up
22
Manual pump control
08
Steady state
23
Inlet leak check
09
Ramp-down
24
System leak check
10
Final ramp-down
This manual is related to the following products: