OPERATION

HPR260 Auto Gas

Instruction Manual

4-45

Part

Check for

Action

10

0

20

40

30

4

0

2

3

1

80

60

70

50

90

Inspect electrode pit depth

Electrode

Center surface

Wear

Replace electrode if pit is deeper than 1 mm (0.040 in.)*

*Always replace the nozzle and electrode as a set.

Electrode pit depth gauge (004630)