Command table (13 of 13) – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 263
APPENDIX B – CNC INTERFACE PROTOCOL
b-18
HPR260 Auto Gas
Instruction Manual
ID
Command
System
Description
126
GET_INFO2
Auto gas control
board only
See 079
127
GET_INFO3
Auto gas control
board only
See 079
131
CLEAR WARNINGS
Manual gas system
Auto gas system
This command will clear error codes less than #43.
Sample:
>13195<
>1311C6<
132
READ COOLANT PRESSURE
HPR260 ONLY
This command returns the raw A/D value for coolant pressure.
83 counts = 225 psi
73 counts = 200 psi
Sample:
>13296<
>13280FE<
Command table (13 of 13)
5