Stainless steel, H35 and n, Plasma / n – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 284: Shield 200 a cutting, Marking, English, Metric

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS
HPR260 Auto Gas
Instruction Manual
c-15
Stainless steel
H35 and N
2
Plasma / N
2
Shield
200 A Cutting
Flow rates – lpm/scfh
H35
N
2
Preflow
0 / 0
116 / 245
Cutflow
11 / 24
118 / 250
Plasma Shield Plasma Shield Plasma Shield
Mix
Gas 1
Mix
Gas 2
mm
Volts
mm factor %
seconds
10
161
0.5
12
162
0.6
15
167
9.0
0.8
20
171
10.0
1.0
Plasma Shield Plasma Shield Plasma Shield
Mix
Gas 1
Mix
Gas 2
in
Volts
in
factor %
seconds
3/8
161
0.5
1/2
162
0.6
5/8
167
0.27
0.8
3/4
171
0.3
1.0
Marking
mm
in
mm/min
N
2
N
2
10
10
10
10
2.5
0.100
6350
18
250
140
Torch-to-Work
Distance
Marking
Speed
Amps
ipm
Volts
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
0.180
60
150
0.200
45
0.160
75
0.320
200
70
in
ipm
H35
N
2
23
49
87
49
42
20
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-
Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce
Delay Time
4.6
1600
150
5.1
1000
4.0
1900
8.0
200
1800
mm
mm/m
H35
N
2
23
49
87
49
42
20
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-
Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce
Delay Time
Arc
Voltage
220345
220398
220307
220344
220342
220343