3-32
HPR260 Auto Gas
Instruction Manual
5c. Slide the sleeve forward until it clicks into place.
5. Connect the pilot arc lead.
Note: Be careful not to damage or remove the small slotted metal band at the end of the pilot arc cable.
5a. Pull the sleeve back until the connector is exposed.
5b. Screw the connector onto the pilot arc connection from the torch. Tighten by hand until it is firmly seated.
6. Connect the plasma-gas vent hose.