Aluminum, H35 and n, Plasma / n – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 291: Shield 130 a cutting, Marking, English, Metric

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS
c-22
HPR260 Auto Gas
Instruction Manual
Aluminum
H35 and N
2
Plasma / N
2
Shield
130 A Cutting
220198
220173
220307
220304
220179
220197
Flow rates – lpm/scfh
H35
N
2
Preflow
0 / 0
97 / 205
Cutflow
13 / 28
71 / 150
Plasma Shield Plasma Shield Plasma Shield
Mix
Gas 1
Mix
Gas 2
mm
Volts
mm factor %
seconds
6
156
10
158
12
159
0.5
15
160
0.8
20
163
1.3
Plasma Shield Plasma Shield Plasma Shield
Mix
Gas 1
Mix
Gas 2
in
Volts
in
factor %
seconds
1/4
156
3/8
158
1/2
159
0.5
5/8
160
0.8
3/4
163
1.3
mm
in
mm/min
N
2
N
2
10
10
10
10
2.5
0.100
6350
18
250
130
Amps
ipm
Volts
Marking
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
0.3
65
0.120
55
0.240
45
35
0.140
85
0.280
200
in
ipm
H35
N
2
19
60
75
27
32
3.5
2215
18
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-
Work
Distance
3.0
1455
6.0
1215
815
mm/m
Pierce
Delay Time
0.3
1615
Cutting
Speed
Initial Pierce
Height
H35
N
2
19
60
Cutting
Speed
Initial Pierce
Height
Pierce
Delay Time
75
27
32
18
7.0
200
mm
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-
Work
Distance
Arc
Voltage
Note: This process produces a smoother cut edge with smaller average angles than the 130A, Air/Air process
5