Install consumables -11, Install consumables – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 105
![background image](https://www.manualsdir.com/files/789725/content/doc105.png)
OPERATION
HPR260 Auto Gas
Instruction Manual
4-11
Install consumables
Do not overtighten parts! Only tighten until mating parts are seated.
Clean the current ring
using a cotton swab with
water or 3% hydrogen
peroxide.
Tool part number
104119
Apply a thin film of silicone lubricant on each o-ring.
5
Install the electrode
Install the swirl ring
Install the nozzle and
swirl ring
Install the inner
retaining cap
Install the shield
Install the
retaining cap
This manual is related to the following products: